NOTICE:
Due to a fire, we are closed this week. Please bear with us as we get our phones back to working condition.
Thank You
v
MMC Phenethylamine Test (2C's - Smiles)
SKU:
FS-MMCPHENTHYLAIME
MMC Phenethylamine Test (2C's - Smiles)
This test is used for the presumptive identification of Phenethylamines (2C's)
10 tests per pack
This test is able to detect:
| 2C-B |
Yellow, changing to green, and then fading over time |
| 2C-C |
Yellow, changing to light green, and then fading over time |
| 2C-D |
Yellow-brown fading to reddish brown |
| 2C-E |
Dark Brown |
| 2C-H |
Dark Green |
| 2C-I |
Green-blue with yellow edges, fades to blue, fades over time |
| 2C-P |
Yellow-brown fading to Rusty Brown |
| 2C-N |
Dark brown with green edges |
| 2C-T-2 |
Black/dark purple fading to orangy-red |
| 2C-T-4 |
Black/dark purple fading to reddish-orange |
| 2C-T-7 |
Black/dark purple, fading slowly if at all. |
| DOB |
Olive Green to yellow |
| DOI |
Dark Green |
| DOM |
Yellow to Green |
| DOC |
Yellow, changing to green. Slow to develop |
| 25C-NBOMe |
Yellow, slow. |
| 25D-NBOMe |
Brown, maybe a hint of green |
| 25I-NBOMe |
Light Brown to dark Brown |
Colors may vary depending on the purity of the sample.
Follow the strict manufacturer's guidelines on how to conduct the test and report the findings. By following this guideline you ensure that the officers are familiar with the procedures and are placed in a position to better succeed.
How to use;

1st. Knock the unopened ampoule several times against a hard surface, so the granules which may be sticking to the inside of the ampoule wall will fall downwards.

2nd; Take the top of the ampoule between the thumb and index finger and snap off the top with the ampoule breaker


3rd. Use the spatula to insert the suspect material into the ampoule (1) or into the plastic cap (2)

4th. For suspect samples in liquid form such as GHB, we advise to use the round end of the supplied spatula or otherwise use a pipette and insert one drop into the ampoule.

5th. With the MMC LSD / Cannabis / V&R andKetamine Test, the plastic lid contains acatalyst grain which, once the material to be tested is inserted in the ampoule,must be mixed using the round tip of the spatula.

6th. Attention! If the ball in the cap sticks against theside, please use a spatula to take it out and, put it in the ampoule and mix it. Place the plastic cap on top of the ampoule.

Compare the color from the reagent granulate with the color line printed on the ampoule.

Since the MMC Tests does not require acid neutralizers (as this is automatically done within the ampoule) you may throw the used ampoules in the trash or glass bin.
Any questions call 800.969.6699, or email us at Sales@FingerprintPads.com
©1999-2026 Connectweb Technologies, Inc.